MODIS/Terra Surface Reflectance 8-Day L3 Global 250m SIN Grid V061
About this dataset
Imagery details
Related datasets
✦ Suggested by OrionAIThe Moderate Resolution Imaging Spectroradiometer (MODIS) Terra MOD09A1 Version 6.1 product provides an estimate of the surface spectral reflectance of Terra MODIS Bands 1 through 7 corrected for atmospheric conditions such as gasses, aerosols, and Rayleigh scattering. Along with the seven 500 meter (m) reflectance bands are two quality layers and four observation bands. For each pixel, a value is selected from all the acquisitions within the 8-day composite period. The criteria for the pixel choice include cloud and solar zenith. When several acquisitions meet the criteria the pixel with the minimum channel 3 (blue) value is used. Known Issues * For complete information about known issues please refer to the MODIS/VIIRS Land Quality Assessment website.
The MOD09GQ Version 6.1 product provides an estimate of the surface spectral reflectance of Terra Moderate Resolution Imaging Spectroradiometer (MODIS) 250 meter (m) bands 1 and 2, corrected for atmospheric conditions such as gasses, aerosols, and Rayleigh scattering. Along with the 250 m surface reflectance bands are the Quality Assurance (QA) layer and five observation layers. This product is intended to be used in conjunction with the quality and viewing geometry information of the 500 m product (MOD09GA). Known Issues * For complete information about known issues please refer to the MODIS/VIIRS Land Quality Assessment website.
The MYD09Q1 Version 6.1 product provides an estimate of the surface spectral reflectance of Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) Bands 1 and 2, corrected for atmospheric conditions such as gasses, aerosols, and Rayleigh scattering. Provided along with the 250 meter (m) surface reflectance bands are two quality layers. For each pixel, a value is selected from all the acquisitions within the 8-day composite period. The criteria for the pixel choice include cloud and solar zenith. When several acquisitions meet the criteria the pixel with the minimum channel 3 (blue) value is used. Known Issues * Prior to the Aqua MODIS launch, Band 6 exhibited several anomalous detectors. Band 6 performance degraded seriously after launch and presently a majority of the Band 6 detectors are non-functional. Science users should read and use the non-functional detector flags and decide for themselves the optimum manner to handle non-functional detector "gaps" for their products. For complete information please refer to the MODIS Characterization Support Team (MCST) website. * For complete information about known issues please refer to the MODIS/VIIRS Land Quality Assessment website.
The MOD09GA Version 6.1 product provides an estimate of the surface spectral reflectance of Terra Moderate Resolution Imaging Spectroradiometer (MODIS) Bands 1 through 7, corrected for atmospheric conditions such as gasses, aerosols, and Rayleigh scattering. Provided along with the 500 meter (m) surface reflectance, observation, and quality bands are a set of ten 1 kilometer (km) observation bands and geolocation flags. The reflectance layers from the MOD09GA are used as the source data for many of the MODIS land products. Known Issues * For complete information about known issues please refer to the MODIS/VIIRS Land Quality Assessment website.
The Moderate Resolution Imaging Spectroradiometer (MODIS) Aqua MYD09A1 Version 6.1 product provides an estimate of the surface spectral reflectance of Aqua MODIS Bands 1 through 7 corrected for atmospheric conditions such as gasses, aerosols, and Rayleigh scattering. Along with the seven 500 meter (m) reflectance bands are a quality layer and four observation bands. For each pixel, a value is selected from all the acquisitions within the 8-day composite period. The criteria for the pixel choice include cloud and solar zenith. When several acquisitions meet the criteria the pixel with the minimum channel 3 (blue) value is used. Known Issues * Prior to the Aqua MODIS launch, Band 6 exhibited several anomalous detectors. Band 6 performance degraded seriously after launch and presently a majority of the Band 6 detectors are non-functional. Science users should read and use the non-functional detector flags and decide for themselves the optimum manner to handle non-functional detector "gaps" for their products. For complete information please refer to the MODIS Characterization Support Team (MCST) website. * For complete information about known issues please refer to the MODIS/VIIRS Land Quality Assessment website.
The MOD09CMG Version 6.1 product provides an estimate of the surface spectral reflectance of Terra Moderate Resolution Imaging Spectroradiometer (MODIS) Bands 1 through 7, resampled to 5600 meter (m) pixel resolution and corrected for atmospheric conditions such as gasses, aerosols, and Rayleigh scattering. The MOD09CMG data product provides 25 layers including MODIS bands 1 through 7; Brightness Temperature data from thermal bands 20, 21, 31, and 32; along with Quality Assurance (QA) and observation bands. This product is based on a Climate Modeling Grid (CMG) for use in climate simulation models. Known Issues * For complete information about known issues please refer to the MODIS/VIIRS Land Quality Assessment website.
Indexed by OrionGIS from NASA Earthdata (CMR-STAC, LP DAAC cloud). Data is loaded from the publisher's own server when you use it. Permanent link